Skip to main content

Table 8 Total damping force comparison for the optimized MR damper

From: Geometric parameter optimization of magneto-rheological damper using design of experiment technique

Current (A)

Total damping force - FEM model (N)

Total damping force - experimental (N)

Percentage error of experimental results with relation to FEM one

0.10

314.18

331.20

5.42

0.20

476.26

501.81

5.37

0.30

583.67

609.79

4.48

0.40

649.10

668.99

3.06

0.50

688.12

707.99

2.89

0.60

712.92

731.40

2.59