Skip to main content

Table 15 Charpy V-notch impact test results for various areas of the weld

From: Evaluation of applicability of thick E500 TMCP and F500W QT steel plates for Arctic service

Steel grade and plate thickness

Welding process

Impact energy, J

+20 °C

−20 °C

−40 °C

−60 °C

Welded metal

Welded metal

Fusion line

2 mm from the fusion line, HAZ

Welded metal

Fusion line

2 mm from the fusion line, HAZ

Welded metal

E500, 25 mm

MMA

61.2

85.3

112.7

66.2

74.2

81.9

241.4

256.8

271.9

39.5

50.6

79.7

50.7

56.7

62.7

207.9

210.0

234.0

FCAW

170.9

189.0

206.8

91.9

108.3

122.3

206.3

218.4

233.8

88.2

98.0

108.4

60.5

85.7

110.9

208.7

218.1

222.7

SAW

86.8

126.8

143.4

82.4

83.2

95.7

277.5

282.9

288.3

49.3

47.6

84.6

63.4

68.8

74.5

214.6

216.3

222.2

F500W, 35 mm

MIG/MAG

123.5

161.1

159.7

91.7

95.3

104.6

67.1

73.5

76.6

SAW

159.2

163.0

170.4

74.3

77.5

82.8

61.3

61.6

69.7