Skip to main content

Table 1 Grid tests for the Nusselt number at Re = 100

From: Characterization the effects of nanofluids and heating on flow in a baffled vertical channel

Grid no.

Expansion factor (first/last)

Nusselt number

x-direction

y-heading

x-direction

y-heading

100

50

0.1

0.285

1.75485

60

1.77592

70

1.80250

120

50

1.75856

60

1.77922

70

1.80828

140

50

1.76701

60

1.78369

70

1.81702