From: Parametric optimization of corrosion and wear of electroless Ni-P-Cu coating using grey relational coefficient coupled with weighted principal component analysis
Parameters
Values
Nickel sulphate (g/l)
25 to 35
Sodium hypophosphite (g/l)
10 to 20
Sodium citrate (g/l)
15
Copper sulphate (g/l)
0.3 to 0.7
pH
9.5
Temperature (°C)
85
Duration of coating (h)
2
Bath volume (ml)
200