Skip to main content

Table 1 Percentage differences comparison of maximum achievable head and flow of different stages of impedance pump

From: Performance evaluation of multi-stage open-loop impedance pump

Stage (s)

Pressure head (%)

Flow rate (%)

1

Benchmark

Benchmark

2

33.3

35

3

60

110

4

46.7

27